Replacing a GORE® PolyVent? Match four numbers first.

A part that screws into the same M12 hole is not the same part. Four numbers decide whether a second source behaves like the one on your drawing: thread and pitch, airflow at a stated pressure, water entry pressure, and temperature range. Everything else is appearance.

The comparison

Four numbers, and the IP code is not one of them.

The thread and its pitch decide whether the part goes in the hole. Airflow at a stated pressure difference decides whether the cabinet equalises fast enough. Water entry pressure decides what the IP code actually means in your application. Temperature decides whether the O-ring and the membrane survive the duty cycle. IP68 on its own decides nothing, because the second digit is agreed between the maker and the test house.

SeriesThreadPart numbersAirflowΔp = 70 mbarBody
PolyVent XSM6 × 0.75PMF100600300 ml/minPA6/66
PolyVent StandardM12 × 1PMF100318 blk / PMF100319 gry450 ml/minPA66 + PA6
PolyVent StandardM12 × 1.5PMF100320 blk / PMF100321 gry450 ml/minPA66 + PA6
PolyVent High AirflowM12 × 1.5PMF100585 blk / PMF100586 gry4,000 ml/minPA6
PolyVent High Airflow PROM12 × 1PMF300670 blk / PMF300671 gry7,600 ml/minPA66 + PA6
PolyVent High Airflow PROM12 × 1.5PMF300680 blk / PMF300681 gry7,600 ml/minPA66 + PA6
PolyVent Stainless SteelM12 × 1.5PMF2004441,600 ml/min316L
PolyVent Ex+M12 × 1.5PMF2004001,600 ml/min316L
PolyVent XLM32 × 1.5PMF20054216 l/min @ Δp 12 mbarPC

Figures as published by W. L. Gore & Associates and by distributors carrying its datasheets, read 9 November 2026. They are here so you have something to compare against — we do not supply them.

Read the thread column down. Six of the nine parts are M12, at two different pitches, in five different bodies, with airflow from 450 to 7,600 ml/min on the same thread diameter. A drawing that says “M12 Gore vent” has not specified a part yet — the series name is the specification.

The trap

An airflow figure without its test pressure is not a number.

Flow through a membrane rises with the pressure difference across it, and not in a straight line. So 4,000 ml/min and 16 l/h cannot be put side by side until both are pinned to the same delta-p. Across the catalogue pages we read for this, the pressures actually in use were 70 mbar, 0.1 bar, 0.2 bar, 0.6 bar, 0.8 bar and 7 kPa — a spread of more than ten to one.

Taken at face value the arithmetic flatters the wrong part. 16 l/h is 267 ml/min, which reads as roughly two thirds of a PolyVent Standard at 450 ml/min. But those 16 litres are quoted at 0.8 bar, eleven times the pressure Gore quotes at. Measured at 70 mbar the same part would pass a small fraction of that.

The rule that follows is mechanical: convert every figure to the same unit, and refuse any figure that does not state its pressure. A supplier who cannot give you the delta-p does not have the number — they have a sentence.

Before you compare two figures

  • Convert. 1 mbar = 100 Pa. 7 kPa = 70 mbar. 0.1 bar = 100 mbar. Three suppliers can quote the same test in three units.
  • Match the delta-p. Two figures at 70 mbar are comparable. One at 70 mbar and one at 0.8 bar are not, in either direction.
  • Check the unit. ml/min and l/h differ by a factor of 60. Both appear in this market on the same size of part.
  • Ask what was measured. A bare membrane coupon and a finished part in its housing do not pass the same air.
The part nobody prints

Airflow and water entry are bought with the same money.

Three suppliers publish four grades of one M12 body and print both numbers for every grade. Line them up and the trade is arithmetic, not opinion.

SupplierGradeAirflowWater entryheld pressure
OrtacOMVPL01S16 L/h0.8 bar
OrtacOMVPL01M25 L/h0.5 bar
OrtacOMVPL01H150 L/h0.2 bar
OrtacOMVPL01UH300 L/h0.1 bar
Fastpoint8257AA low16 L/h0.8 bar
Fastpoint8257AA high133 L/h0.2 bar
Fastpoint8257AA ultra300 L/h0.1 bar
Newelfin010VV40024 L/h0.6 bar
Newelfin010VV120 L/h0.2 bar
Newelfin010VV12500750 L/h0.1 bar

Read from each supplier's own product page on 28 October 2026, reproduced here as published. The thread is identical in all ten rows.

Eight times the airflow, an eighth of the water head — in all three columns, in both directions. What changes between the grades is the membrane area behind the thread and how the housing seals around it, not the thread itself.

This is the part of second sourcing that goes wrong quietly. A buyer who asks for “more airflow than the existing part” receives a part that passes more air and holds less water. The cabinet passes its IP test at the factory, and shows water after a season of rain. If the thread cannot grow, extra airflow can only come from a thinner or more open membrane, and water entry follows it down.

So specify it backwards

Decide the water entry pressure your installation actually has to survive first — jet wash, driving rain, temporary immersion — and then take the lowest airflow that still equalises the cabinet inside the time you need. Not the highest airflow the catalogue offers.

For the arithmetic of how much air a cabinet has to move, and the pressure it develops per temperature swing, see vent sizing for battery storage cabinets.

The checklist

Six lines on the RFQ, and the answer becomes checkable.

These cost nothing to ask for and they separate a supplier who has measured from one who has copied a competitor's table.

  • Thread and pitch. M12 × 1 and M12 × 1.5 are not the same hole, and both are sold under the same series name. The pitch is invisible once the part is in the panel.
  • Airflow, with the pressure difference it was measured at — and the unit. A figure without its Δp is a sentence, not a specification.
  • Water entry pressure in bar, with the hold time. Not the IP code on its own.
  • Operating temperature range, and whether that limit belongs to the membrane or to the O-ring. They are not the same number.
  • O-ring material, hardness and tightening torque. Silicone 60 Shore A and nitrile do not age the same way, and half a newton-metre is enough to change the seal.
  • Whether the membrane is oleophobic. In a cabinet with oil mist, a gearbox breather nearby or a compressor on the same skid, a hydrophobic-only membrane wets out and stops breathing without ever leaking.
Where we stand

Data, or an honest gap where the data is not there.

On our own vent plug range: PA66 bodies from M5 to M40 with a laminated ePTFE membrane, IP68, −40 to +105 °C, black, white or grey, and M18 × 1.5 built to order. What we do not publish is a full airflow table for every size, because we have not measured every size — and a table padded with numbers we cannot support is worse than an empty cell. The first customer who checks it takes the whole catalogue down with it.

  • On the quotationThread and pitch, airflow at the pressure you asked about, water entry pressure with its hold time, and the temperature range — or an explicit note saying which of the four we cannot document.
  • On requestThe test report behind the IP code, O-ring material and hardness, and the recommended tightening torque.
  • Not offeredThe word “equivalent”, and any number we cannot put a source against.
Before you decide

The questions second sourcing actually runs into.

If you send us the four numbers from your drawing — thread, airflow and its pressure, water entry, temperature — we will tell you which of them we can meet and which we cannot, before any sample ships.

Is Honvale affiliated with W. L. Gore & Associates?
No. GORE and PolyVent are trademarks of W. L. Gore & Associates, Inc. Honvale is an independent supplier based in Chongqing, China, and is not authorised, endorsed, sponsored or licensed by Gore. Gore part numbers and published figures appear on this page so that you have something to compare against.
Can I put a GORE part number on the RFQ?
Yes, and it saves a round of questions — it tells us the thread and the performance class you have designed around. What you will not get back is the word "equivalent". You will get our thread, our airflow at a stated pressure, our water entry pressure and our temperature range, and you can see for yourself where the two differ. If one of the four cannot be met, the quotation will say which one.
M12 × 1 or M12 × 1.5 — does it matter?
It is a different hole. Gore sells both under PolyVent Standard: PMF100318 and PMF100319 are M12 × 1, PMF100320 and PMF100321 are M12 × 1.5. Because the pitch cannot be seen with the part fitted, a mixed bin at the assembly station is a real failure mode, and it only shows up as a leak months later.
If a vent passes more air, does it keep the same IP rating?
It can carry the same IP code and still hold less water. IP is a pass/fail test at conditions the maker and the test house agree on; water entry pressure is the number that tells you the margin. Two parts both marked IP68 can differ by a factor of eight in the pressure they hold.
Does IP68 tell me the depth and the time?
No. For the 8 in IPX8 the depth and duration are set by the manufacturer's own specification, so they have to be read off the datasheet and compared. A part tested at 1 m for 30 minutes and one tested at 2 m for an hour both read IP68, and they are not the same product.