A part that screws into the same M12 hole is not the same part. Four numbers decide whether a second source behaves like the one on your drawing: thread and pitch, airflow at a stated pressure, water entry pressure, and temperature range. Everything else is appearance.
The thread and its pitch decide whether the part goes in the hole. Airflow at a stated pressure difference decides whether the cabinet equalises fast enough. Water entry pressure decides what the IP code actually means in your application. Temperature decides whether the O-ring and the membrane survive the duty cycle. IP68 on its own decides nothing, because the second digit is agreed between the maker and the test house.
| Series | Thread | Part numbers | AirflowΔp = 70 mbar | Body |
|---|---|---|---|---|
| PolyVent XS | M6 × 0.75 | PMF100600 | 300 ml/min | PA6/66 |
| PolyVent Standard | M12 × 1 | PMF100318 blk / PMF100319 gry | 450 ml/min | PA66 + PA6 |
| PolyVent Standard | M12 × 1.5 | PMF100320 blk / PMF100321 gry | 450 ml/min | PA66 + PA6 |
| PolyVent High Airflow | M12 × 1.5 | PMF100585 blk / PMF100586 gry | 4,000 ml/min | PA6 |
| PolyVent High Airflow PRO | M12 × 1 | PMF300670 blk / PMF300671 gry | 7,600 ml/min | PA66 + PA6 |
| PolyVent High Airflow PRO | M12 × 1.5 | PMF300680 blk / PMF300681 gry | 7,600 ml/min | PA66 + PA6 |
| PolyVent Stainless Steel | M12 × 1.5 | PMF200444 | 1,600 ml/min | 316L |
| PolyVent Ex+ | M12 × 1.5 | PMF200400 | 1,600 ml/min | 316L |
| PolyVent XL | M32 × 1.5 | PMF200542 | 16 l/min @ Δp 12 mbar | PC |
Figures as published by W. L. Gore & Associates and by distributors carrying its datasheets, read 9 November 2026. They are here so you have something to compare against — we do not supply them.
Read the thread column down. Six of the nine parts are M12, at two different pitches, in five different bodies, with airflow from 450 to 7,600 ml/min on the same thread diameter. A drawing that says “M12 Gore vent” has not specified a part yet — the series name is the specification.
Flow through a membrane rises with the pressure difference across it, and not in a straight line. So 4,000 ml/min and 16 l/h cannot be put side by side until both are pinned to the same delta-p. Across the catalogue pages we read for this, the pressures actually in use were 70 mbar, 0.1 bar, 0.2 bar, 0.6 bar, 0.8 bar and 7 kPa — a spread of more than ten to one.
Taken at face value the arithmetic flatters the wrong part. 16 l/h is 267 ml/min, which reads as roughly two thirds of a PolyVent Standard at 450 ml/min. But those 16 litres are quoted at 0.8 bar, eleven times the pressure Gore quotes at. Measured at 70 mbar the same part would pass a small fraction of that.
The rule that follows is mechanical: convert every figure to the same unit, and refuse any figure that does not state its pressure. A supplier who cannot give you the delta-p does not have the number — they have a sentence.
Three suppliers publish four grades of one M12 body and print both numbers for every grade. Line them up and the trade is arithmetic, not opinion.
| Supplier | Grade | Airflow | Water entryheld pressure |
|---|---|---|---|
| Ortac | OMVPL01S | 16 L/h | 0.8 bar |
| Ortac | OMVPL01M | 25 L/h | 0.5 bar |
| Ortac | OMVPL01H | 150 L/h | 0.2 bar |
| Ortac | OMVPL01UH | 300 L/h | 0.1 bar |
| Fastpoint | 8257AA low | 16 L/h | 0.8 bar |
| Fastpoint | 8257AA high | 133 L/h | 0.2 bar |
| Fastpoint | 8257AA ultra | 300 L/h | 0.1 bar |
| Newelfin | 010VV400 | 24 L/h | 0.6 bar |
| Newelfin | 010VV | 120 L/h | 0.2 bar |
| Newelfin | 010VV12500 | 750 L/h | 0.1 bar |
Read from each supplier's own product page on 28 October 2026, reproduced here as published. The thread is identical in all ten rows.
Eight times the airflow, an eighth of the water head — in all three columns, in both directions. What changes between the grades is the membrane area behind the thread and how the housing seals around it, not the thread itself.
This is the part of second sourcing that goes wrong quietly. A buyer who asks for “more airflow than the existing part” receives a part that passes more air and holds less water. The cabinet passes its IP test at the factory, and shows water after a season of rain. If the thread cannot grow, extra airflow can only come from a thinner or more open membrane, and water entry follows it down.
Decide the water entry pressure your installation actually has to survive first — jet wash, driving rain, temporary immersion — and then take the lowest airflow that still equalises the cabinet inside the time you need. Not the highest airflow the catalogue offers.
For the arithmetic of how much air a cabinet has to move, and the pressure it develops per temperature swing, see vent sizing for battery storage cabinets.
These cost nothing to ask for and they separate a supplier who has measured from one who has copied a competitor's table.
On our own vent plug range: PA66 bodies from M5 to M40 with a laminated ePTFE membrane, IP68, −40 to +105 °C, black, white or grey, and M18 × 1.5 built to order. What we do not publish is a full airflow table for every size, because we have not measured every size — and a table padded with numbers we cannot support is worse than an empty cell. The first customer who checks it takes the whole catalogue down with it.
If you send us the four numbers from your drawing — thread, airflow and its pressure, water entry, temperature — we will tell you which of them we can meet and which we cannot, before any sample ships.