Home/Products/Cable Glands

Stainless steel cable glands

Every power and signal cable that crosses the wall of a sealed cabinet crosses it through a gland. We supply machined 304 and 316 stainless glands in metric, PG, NPT and G thread forms — with the seal compound, temperature range and IP report verified before any number goes on a datasheet.

The part buyers get wrong

A gland seals in three places at once.

Two of those places are on your side of the wall, and none of them is on the datasheet. That is why two identical glands can give completely different results on two different machines — and why "IP68 gland" on its own is an incomplete specification.

The seal is made on the cable sheath by the compression insert, on the enclosure entry face by the O-ring, and at the locknut by the torque you apply. Get the clamping range right for the cable, the thread right for the hole, and the gland will do its job for years. Get any one of them wrong and water finds it on the first storm.

So we ask for two numbers before we quote: your cable outside diameter, and the thread of the hole you are entering. Everything else — body material, seal compound, thread length — follows from those two.

Three seals, three failure modes

  • Cable sheath. The insert must sit inside its clamping range. A gland sized for 13–18 mm fitted to a 9 mm cable cannot compress the seal, whatever the torque.
  • Entry face. Parallel threads (M, PG, G) seal on a face O-ring. NPT is tapered and seals on the thread itself — which is why it needs sealant, not an O-ring.
  • Locknut. Under-torqued and it weeps. Over-torqued and you crush the gasket, damage the thread or crack a thin panel. Hand-tight plus a quarter turn is the working rule.
  • Unused openings. A knockout left open defeats the whole enclosure. Tell us the thread and we will quote sealing plugs in the same order.
Thread families

Four thread systems. They do not interchange.

Match the gland to the hole you already have. The thread form is decided by the panel standard, not by preference — and forcing the wrong one in will strip the thread, not seal it.

Metric · M

Metric thread

Diameter and pitch written directly — M20×1.5 means a 20 mm nominal diameter on a 1.5 mm pitch. The IEC and European default, and the most common entry on modern enclosures. If you are specifying a new panel, this is almost always the right choice.

  • Sizes from M8×1 to M100×1.5
  • Parallel thread — seals on a face O-ring
  • Standard on energy storage, EV charging and outdoor telecom cabinets
M8 – M100 Ask
PG · conduit

PG thread

A legacy German conduit standard still found across Europe and on imported machinery. The size is a number rather than a diameter, so PG13.5 does not mean 13.5 mm of anything — read the table. Common on panels specified before metric became the default.

  • Sizes from PG7 to PG63
  • Not interchangeable with metric — different pitch as well as diameter
  • Available for retrofit on existing panels
PG7 – PG63 Ask
NPT · tapered

NPT thread

The North American tapered pipe thread. It seals by mechanical interference as it is tightened — no face O-ring is involved, and a thread sealant is required on assembly. Specified for enclosures built to NEMA conventions and for a lot of Latin American and Middle East projects working to ANSI equipment.

  • Sizes from NPT1/4 to NPT3
  • Tapered thread — sealant required, O-ring not used
  • Often mistaken for G thread — they are different standards
NPT1/4 – NPT3 Ask
G · BSPP

G / BSPP thread

Parallel pipe thread used on process, marine and hydraulic-adjacent equipment. It looks close enough to NPT to be confused in an enquiry, and neither will seal properly in the other's hole. If your panel came from a process plant, check before ordering.

  • Sizes from G1/4 to G3
  • Parallel thread — seals on a face washer
  • Send a photo with a rule and we will identify it for you
G1/4 – G3 Ask
Selection

Three answers and we can quote the part.

Gland selection is two mechanical matches and one environmental choice. Nothing here needs a calculation — it needs a caliper and a look at where the cabinet is installed.

What to send us

  • Cable ODOutside diameter of the cable or cable bundle, in mm. This decides the size, not the conductor cross-section.
  • ThreadThe thread of the hole, or a photo with a rule across the entry. M, PG, NPT and G are all different.
  • EnvironmentCoastal or offshore, wash-down, oil mist, chemical exposure — this picks 304 or 316 and the seal compound.
  • Volume / yrAnnual quantity and destination, so we can quote the right Incoterm and packaging.
Reference

Typical size correspondence.

Common industry values, shown so you can sanity-check a hole before you send us a drawing. Clamping range and thread length vary between manufacturers — treat this as a guide and confirm against the actual part number before you commit a knockout.

Thread Typical cable range Entry to cut
M12×1.53 – 6.5 mm12.0 mm
M16×1.54 – 8 mm16.0 mm
M20×1.56 – 12 mm20.0 mm
M25×1.513 – 18 mm25.0 mm
M32×1.516 – 23 mm32.0 mm
M40×1.524 – 32 mm40.0 mm
PG94 – 8 mm15.2 mm
PG13.56 – 12 mm20.4 mm
PG1610 – 14 mm22.5 mm
PG2113 – 18 mm28.3 mm
NPT1/26 – 12 mm21.2 mm
NPT3/413 – 18 mm26.5 mm

Thread outside diameters are nominal and shown to one decimal. Consult the part drawing for tapped-hole tolerances.

One programme

The gland is one of four openings in the same cabinet.

Power crosses the wall through a gland, but the same cabinet also has to breathe and to shed pressure. Buying all of it from one place means one specification conversation, one packing list and one shipping cost.

Breathing port

A laminated ePTFE membrane equalises internal pressure without passing liquid water, so the door gasket stays in its compression range.

Vent plugs Open

Pressure relief

A spring-loaded valve for fast pressure rises a membrane cannot absorb, and the anti-icing seat for cold-climate duty cycles.

Relief valves Open

Combined kits

Glands, vents and plugs kitted per cabinet and labelled per your bill of materials, so the line receives one kit instead of three deliveries.

On request Ask

If the cabinet needs to breathe at the entry the cable already uses, there is a vented version of the gland itself: breathable cable glands. For the whole wall rather than a single product, see sealing every opening in an outdoor cabinet.

Common questions

Straight answers.

The questions that come up before a first gland order. If yours is not here, ask — we answer with a number, a drawing or an honest "not yet".

Are M and PG glands interchangeable?
No. Metric and PG threads have different diameters and different pitches, and neither seals in the other's hole. An M20 gland needs an M20 tapped entry; a PG13.5 gland needs a PG13.5 entry. Sizing is two separate checks — cable outside diameter for the clamping range, tapped hole for the thread.
Is the IP rating a property of the gland itself?
Not on its own. The gland seals on the cable sheath, on the entry face and at the locknut. What you actually get is a combination of the gland, the cable sitting inside its clamping range, and the install torque. A correctly specified gland on an undersized cable will not hold its rating.
Which thread form does my enclosure use?
Metric is the IEC and European default. PG appears on older German-specified panels. NPT is the North American tapered standard. G (BSPP) shows up on process and marine equipment. If you are unsure, send a photo of the entry next to a rule and we will identify it from the outside diameter and pitch.
What seal compound do I need?
EPDM is the general-purpose choice for water and weather. NBR resists oil and petroleum products. Silicone covers temperature extremes. FKM (Viton) is for aggressive chemicals and solvents. Tell us what the enclosure is exposed to and we will specify the compound instead of leaving it at a default.
Can you supply 316L, EMC or explosion-proof versions?
316 stainless is available as standard, and 316L on request. EMC (shielded) and explosion-proof types sit on a different certification route, so ask us directly and we will tell you plainly what we can supply now and what would carry a certification lead time.
What documentation comes with an order?
A dimensional drawing and a material certificate for the stainless grade on request. The independent IP report for this range is being arranged — ask for the current status on your part number, and we will tell you exactly where it stands rather than quoting a rating we cannot yet evidence.
Next step

Send the cable OD and the thread. Get a part number back.

Two numbers are enough to quote. If you are not sure of the thread, a photo of the entry with a rule across it works just as well.