A gland takes a cable through a wall. A junction connector takes one cable into another. A cabinet that is sealed at every entry still leaks at the joint somebody taped up on site, and that joint is the one part nobody puts on the drawing.

Where these get specified

The joint, not the entry, is where water gets in.

Every cable entry on the cabinet gets a gland, a torque figure and a line on the drawing. The branch two metres down the run gets none of that. The sheath is opened, the conductors are joined, and the result is potted, taped or heat-shrunk — three methods that all have to be destroyed before the joint can be inspected.

A screw-terminal connector keeps the joint re-openable. The cap unscrews, the terminal block inside is the same 2-, 3- or 5-pole block that would sit in a junction box, and the seal is a compressed gasket rather than a pour. That matters on a cabinet commissioned in stages, or where a loom is re-terminated after a site fault.

Four bodies cover the shapes a loom actually takes: straight for a pull-through, T and Y where a run branches, cross where two runs meet. All of them are M20 to M28, which is the same thread family the glands on the cabinet use.

Three ways to close a joint

  • Potting compound. Cheap per joint, permanent, and it has to be cut away before anyone can look at the connection again.
  • Heat-shrink. Needs a heat source on site, and cannot be re-entered without cutting it off.
  • Screw-terminal connector. Re-openable with one screwdriver, sealed by a gasket, terminal block accessible without disturbing the cable.
  • Each entry is independent. Its own cap, its own insert, its own claw — so one loose entry does not disturb the two beside it.
Internal construction

Each entry clamps its own cable.

Six parts, and every entry clamps on its own cable. The claw and the insert sit inside the cap, so the compression is set by how far the cap runs down — not by how hard somebody pulled the cable.

Exploded diagram of an IP68 junction connector showing clamping cap, sealing insert, clamping claw, screw terminal block, sealing gasket and PA66 body
01

Clamping cap

Screws down over the insert and drives the compression. Running the cap down is what sets the seal; the thread is what holds it there.

02

Sealing insert

The yellow gasket that closes on the cable sheath. It has a range, not a single diameter — a cable below the bottom of that range cannot be compressed onto, whatever the torque.

03

Clamping claw

Takes the pull. This is what stops a tug on the loom transferring into the terminal screws, and it is the part that gets left out when somebody re-assembles a joint in a hurry.

04

Screw terminal block

2-, 3- or 5-pole depending on the body. Accessible from the open entry, so the connection can be checked without cutting the seal or disturbing the other cables.

05

Sealing gasket

Body to body, where the entry collar meets the trunk. This face is the one a customer never checks, and it is the first one left out when a joint is re-assembled in a hurry.

06

PA66 body

PA66 nylon, rated −40 to +105 °C. The thread is moulded rather than machined, so the tightening torque that applies to a stainless gland does not carry over to this body — snug it down and stop.

Because each entry carries its own cap and insert, three cables of different outside diameters can share one body — provided each one sits inside its entry's range. That is the whole reason the entries are independent rather than one moulded block.

The range

Eighteen part numbers across four bodies.

Three thread sizes, four body shapes, three pole counts. Any of them can be quoted against the cable outside diameter you actually have rather than against the catalogue range.

IP68 waterproof junction connectors: M20 cross body and M28 straight body with a cap and yellow sealing insert laid out beside them, PA66 black bodies
Cross body and straight body, both PA66. On the left a cap is off one entry — that is where the yellow insert sits, and the insert is the part that compresses on the sheath.

M20 and M25 — six part numbers

CodeBodyThreadPolesCable rangeConductor
JC-T20-2T branchM20×1.52P5 – 12 mm0.5 – 4 mm²
JC-T20-3T branchM20×1.53P5 – 12 mm0.5 – 4 mm²
JC-X20-2CrossM20×1.52P5 – 12 mm0.5 – 4 mm²
JC-X20-3CrossM20×1.53P5 – 12 mm0.5 – 4 mm²
JC-Y25-3Y branchM253P9 – 12 mm0.5 – 2.5 mm²
JC-Y25-5Y branchM255P9 – 12 mm0.5 – 2.5 mm²

The M20 body covers 5–12 mm at every entry; the M25 body is Y-shaped only and covers 9–12 mm. Packed weight across the four M20 bodies runs 60 g to 96 g including the bag — the M25 and M28 bodies are weighed when they are packed, so ask for the figure if you are costing air freight.

M28 — twelve part numbers

CodeBodyThreadPolesCable rangeConductor
JC-D28-3SStraightM283P10 – 14 mm0.5 – 6 mm²
JC-D28-3LStraightM283P14 – 18 mm0.5 – 6 mm²
JC-D28-5SStraightM285P10 – 14 mm0.5 – 6 mm²
JC-D28-5LStraightM285P14 – 18 mm0.5 – 6 mm²
JC-T28-3ST branchM283P10 – 14 mm0.5 – 6 mm²
JC-T28-3LT branchM283P14 – 18 mm0.5 – 6 mm²
JC-T28-5ST branchM285P10 – 14 mm0.5 – 6 mm²
JC-T28-5LT branchM285P14 – 18 mm0.5 – 6 mm²
JC-X28-3SCrossM283P10 – 14 mm0.5 – 6 mm²
JC-X28-3LCrossM283P14 – 18 mm0.5 – 6 mm²
JC-X28-5SCrossM285P10 – 14 mm0.5 – 6 mm²
JC-X28-5LCrossM285P14 – 18 mm0.5 – 6 mm²

The suffix is the insert, not the body: S is the 10–14 mm insert and L is the 14–18 mm insert, and the same M28 body takes either. Every shape comes in 3-pole and 5-pole. Pick on the cable, not on the shape — a 12 mm sheath cannot be closed down by an L insert and a 16 mm sheath will not enter an S.

Ratings that apply to every body

ParameterValue
SealingIP68
Rated voltage400 – 450 V
Rated current16 A / 17.5 A / 24 A / 40 A across the range
Body materialPA66, flame-retardant grade
TerminalsScrew clamp, re-openable
Temperature−40 to +105 °C

The current is published as four figures for the family rather than one per part number, and the voltage as a window rather than a single value. That is what the sheet says, so that is what is printed here. Give us the load and the conductor size and the figure gets pinned to the exact part number.

The two numbers that trip up a BOM line, the amp figure quoted without a conductor and the entry whose insert does not match the sheath, are worked through in IP68 junction connector: the weakest entry sets the rating.

Sizing

Three answers and the part number falls out.

No sizing chart needed. A junction connector is decided by the shape of the run and the cable that goes into it.

Step 01

How many directions

Two directions through the body: straight. Three: T or Y. Four: cross. The difference between T and Y is the angle the branch leaves at, which is set by how much room the loom has behind the joint.

Straight / T / Y / cross
Step 02

Cable outside diameter

This picks the insert, and the insert is what actually seals. Measure the sheath, not the conductor and not the nominal size of the cable. A 5–12 mm entry will not grip a 4 mm lead however far the cap runs down.

5 – 18 mm
Step 03

Terminals inside

2-pole on the M20 only, 3-pole and 5-pole on all three sizes. This is the count of conductors the block joins — it does not have to match the number of entries, and it is the specification most often written down wrongly on a first enquiry.

2P / 3P / 5P

Temperature range is −40 to +105 °C for the PA66 bodies. That is a narrower window than a stainless gland, and worth checking against the enclosure it sits in rather than assuming the two match.

Don't mix the two up

A junction connector does not replace a gland.

They solve two different problems — one is a wall, the other is a splice. Getting the wrong one costs a second shipment, so this is the shortest version of the difference.

Cable glandJunction connector
Where it sitsOn the enclosure wallAnywhere along the cable run
What it joinsCable to enclosureCable to cable
Tapped hole neededYes — M, PG, NPT or GNo
Holds a cable under pullYes, through the clawYes, but the joint is not a fixing point — support the loom
Re-openableCap onlyCap and terminal block

A joint in mid-air still needs mechanical support. The claw stops the terminal screws taking the pull; it does not turn the connector into a cable support, and a joint hanging free on a vibrating machine will fail at the sheath eventually.

Common questions

Straight answers.

The questions that come up before a first order. If yours is not here, ask — the reply will be a number, a drawing or an honest "not yet".

Is a junction connector the same as a cable gland?
No, and they do not substitute for each other. A gland seals one cable to the wall of an enclosure and needs a tapped hole. A junction connector seals one cable to another cable somewhere along the run and needs no hole at all. A cabinet can be correct at every gland and still have an open joint two metres down the loom.
What are these rated for — volts and amps?
The sheet for the range gives 400–450 V and a current figure of 16 A, 17.5 A, 24 A or 40 A. Body is flame-retardant PA66, sealing is IP68, temperature −40 to +105 °C, and the conductor range is 0.5–4 mm² on M20, 0.5–2.5 mm² on M25 and 0.5–6 mm² on M28. Two caveats rather than a sales line: the current is published as a set of four figures for the family, not one number per part number, and a terminal rating is only as good as the conductor screwed into it — a 40 A block with a 1 mm² lead is a 1 mm² joint. Tell us the load and the conductor size and we will put the figure against the exact part number you need.
Does an IP68 rating mean I can bury it?
IP68 is a test condition, not a burial licence. The rating is stated against a depth and a duration by whoever tested the part, and neither of those is soil. Burial adds a permanent water table, ground water chemistry and mechanical load, none of which an immersion test covers. If the joint is going underground, tell us the depth and the soil condition before you order and we will confirm the actual test condition on the part rather than let the number speak for itself.
What cable diameter fits the M20 body?
5 to 12 mm on every M20 entry. Each entry has its own cap and its own insert, so three cables of different outside diameters can share one body — as long as each one sits inside that range. The same body is also listed with 5–8 mm and 7–10 mm inserts for thinner cable, so a 6 mm lead is a question to ask at quotation rather than a rejection. A cable below the bottom of whichever insert you fit will not be gripped however far the cap is turned down, and the seal will fail at the sheath.
Can the joint be re-opened after a fault?
Yes. The cap unscrews, the insert and claw come out, and the terminal block is accessible with a screwdriver. That is the difference between this and a potted or heat-shrunk joint: the connection can be tested and re-terminated on site without cutting anything off.
Do you recommend it for a joint in direct sun?
PA66 with a UV stabiliser is the normal compound for outdoor work, but UV performance is a compounding decision and the IP rating tells you nothing about it. If the joint sits in direct sun for years, say so when you ask for the quote and we will confirm what the current compound is rather than assume.
What documentation comes with an order?
A dimensional drawing for the body you ordered, and the material declaration on request. The IP68 rating is the one stated by the body maker — if your project needs a third-party test report on the finished assembly, ask before you order and we will tell you where that stands instead of quoting a rating we cannot evidence.
Next step

Send the cable OD and the number of cores.

Those two numbers pick the body and the insert. If you already have a gland on the same run, tell us its thread and we will keep the joint in the same family.