CZ6992 Pressure Compensation Element

A nickel-plated brass cable gland with a laminated ePTFE membrane. It seals the cable entry and equalises pressure through the same opening — one hole in the cabinet wall does two jobs.

Specification

Values below are the published figures for the CZ6992. Where a figure is not yet measured for the finished assembly, the table says so instead of quoting a target.

CZ6992 nickel-plated brass ventilated cable gland with ePTFE breather membrane and NBR seals
CZ6992 — published specification
PropertyValue
Part numberCZ6992
TypeMetal ventilated and waterproof connector (cable gland with breather membrane)
Body materialNickel-plated brass
Sealing materialNBR
Threads — metricM10 / M12 / M16 / M18 / M20
Threads — PGPG7 / PG9 / PG11 / PG13.5
Operating temperature−40 °C to +100 °C
Opening pressure70 mbar
MembraneLaminated ePTFE
IP ratingIP68 — as stated by the body maker. No third-party report on the finished assembly is held, and none is claimed.
AirflowData on request. Measured per thread size at a stated test pressure; ask for the figure for your thread.
Unit weightData on request
MOQ, lead time, sample policySee contact

What it does

Two jobs through one opening

A sealed cabinet needs a cable entry and it needs a way to breathe. Cutting two holes means two gaskets, two leak paths and two places to get the torque wrong. The CZ6992 puts the membrane inside the gland body, so the cable enters and the air moves through the same fitting.

Brass where plastic will not hold

The body is nickel-plated brass with NBR seals. That suits wash-down areas, outdoor electrical enclosures and any place where a plastic gland would creep under torque or soften at temperature. If the enclosure only sees indoor temperature swings, the nylon PV series does the same job for less.

What the 70 mbar means

The membrane lets air through slowly. 70 mbar is the pressure at which the assembly is characterised — it is not a relief threshold and it is not a burst rating. For a cabinet that heats and cools over hours, slow equalisation is what you want. For a battery pack that can raise internal pressure in seconds, this part is the wrong choice; use the RV series instead.

Ask for the numbers you need

If your drawing specifies an airflow at a given pressure, send the thread size and the figure and we will confirm whether this body reaches it. If it does not, we will say so.

Where it is used

Three applications where the cable entry and the breather port are the same hole.

Outdoor cabinets and telecom

Cable enters, air equalises, no second knockout. Common on pole-mounted and wall-mounted enclosures where wall area is scarce.

Charging piles

Wash-down rated body with the membrane protected inside the gland. Suits the cable entry on AC wallboxes and DC cabinets.

Energy storage cabinets

Battery cabinets with cable runs and slow thermal breathing. Where the pressure event can be fast, this part is not enough — see the RV series.

Questions this page answers

Is the CZ6992 a cable gland or a vent plug?
Both, in one body. Mechanically it is a cable gland — the cable is clamped and sealed. Functionally it also vents, because the membrane sits in the body. If you only need to vent and no cable passes through, a PV or SV vent plug is simpler and cheaper.
Can it replace a normal cable gland directly?
Yes, if the thread and the cable clamping range match. It is the same thread form and the same footprint. Match the thread and the cable outside diameter together and the swap is direct.
Does the 70 mbar figure mean it opens at 70 mbar?
No. 70 mbar is the pressure at which the airflow is characterised. The membrane is open to air at all times; it does not seal and then pop. If you need a part that stays closed until a set pressure, that is a relief valve, not this.
Is there a third-party IP68 report?
No. IP68 is the figure stated by the body maker. We do not hold a third-party report on the finished assembly and we do not claim one. If your qualification requires it, tell us and we will quote the test.
What is the MOQ and lead time?
Samples are available before a production run. Send the thread size, the cable outside diameter and the quantity you expect, and we will reply with both figures in one working day.

Related