A vent plug with a colour-change strip behind a toughened viewing window. A service engineer reads the state of the membrane from outside the cabinet — without opening it and without a pressure test.
This is an engineering sample. The rows below say what is fixed and what is still open, including the rating, because a design-in decision should not rest on a number we cannot yet support.
| Property | Value |
|---|---|
| Part number | IV-M20 |
| Type | Vent plug with visual failure indicator |
| Thread | M20×1.5 |
| Body material | PC or PA66, UL94 V-0 |
| Indicator | Colour-change strip behind a toughened viewing window |
| Membrane | Laminated ePTFE |
| IP rating | Target: IP68. Not an achieved rating, and no third-party report is held. |
| Production status | Engineering sample — not in series production |
| Operating temperature | Data on request — depends on the final body material |
| Airflow | Data on request — measured per sample build |
| Ordering | Not available for production quantities at this stage |
| For evaluation | Dimensional drawing and current test record on request — contact |
A blocked or wetted membrane still passes an IP68 retest, because the IP code measures ingress and not airflow. A vent can be dead and still pass incoming inspection. Today the only way to find out is to open the cabinet, or to notice that the enclosure is already wet. The IV-M20 puts that answer on the outside of the door.
It does not measure airflow, it does not log anything, and it does not estimate how much life the membrane has left. It shows a state — normal, or not — at the moment somebody looks at it. That is the whole function, and it is deliberately that simple.
IP68 is a target on this part, not an achieved rating. It has not been third-party tested and it is not in series production. That is written here rather than in a footnote because you should not design a service interval around a number we cannot yet support. The current test record is available and says what it says.
The dimensional drawing, the current test record and the sample build. If your programme needs a different thread or a different body material, say so early — the tooling decision has not been made, which is exactly when a change is still cheap.
Three settings where reading a vent from the outside is worth paying for.
A service visit is expensive and the cabinet stays closed between maintenance rounds. A state that can be read at the door turns a call-out into a glance.
The technician is already on site for something else. If the vent can be read at the same time, the second visit does not happen.